SINAMICS DC governor maintenance
Publish:Shenzhen City Jia Hong Wei Technology Co., Ltd.  Time:2023-01-29
Siemens SINAMICS DC governor maintenance

Jiahongwei repairs the Siemens SINAMICS DC governor 6RA70, 6RA80 series DC governor, Jiahongwei repairs the Siemens SINAMICS DC governor common faults: undervoltage, lack of phase, weak magnetic excitation fault, unstable speed, low output voltage, burning of silicon controlled rectifier, no excitation voltage, burning of fuse, no display, tripping and burning of fuse, no output, starting fault, unable to reset, module explosion, main board failure, drive board failure, etc, The alarm fault codes of the Siemens SINAMICS DC governor repaired by Jiahongwei include F001, F004, F005, F018, F030, F031, F038, F040F042, F050, F052, F062, F067, F068 and other fault codes. The Siemens SINAMICS 6RA80 series DC governor repaired by Jiahongwei includes 6RA8025, 6RA8028, 6RA2831, 6RA8075, 6RA8078, 6RA8081, 6RA8085 and other series models.

SINAMICS SIEMENS 6RA70 DC Governor Maintenance Indicator Description

1. If the Siemens 6RA70 DC governor is in normal operation, the three indicators will repeat and flash at the same frequency and time interval.

2. If an indicator light of Siemens 6RA70 DC governor is continuously on or off, it means that the corresponding state of the indicator light has abnormal fault.

3. Siemens 6RA70 DC governor red light: flashing, indicating that CBP operation power is connected;

Yellow light: flashing, indicating error-free data exchange with equipment;

Green light: flashing, indicating no error in data transmission through PROFIBUS;

4. Siemens 6RA70 DC governor red light: long dark or long light, indicating that the CBP power supply does not work.

Yellow light: long dark or long light, indicating abnormal data exchange with equipment

Green light: long dark/long light, which means that the data format transmitted by PROFIBUS is incorrect, or the PROFIBUS cable is not connected or damaged

5. The flashing red light means that the CBP board is waiting for initialization

The yellow light is dim

The green light stays on

6. The red light is on for a long time, which means that CBP is waiting to complete initialization

The yellow light is dim

Green light flashing

Siemens SINAMICS DC governor alarm fault code

F4000 socket X100 fault

F40001 socket X101 fault

F40002 socket X102 fault

F40003 socket X103 fault

F40004 socket X104 fault

F40005 socket X105 fault

F40799 CX32: The defined transfer end point has been exceeded

F40801 CX32: Missing steroid symbol

F40820 CX32: Message failure

F40825 CX32: Power supply voltage fault

F40835 CX32: Cyclic Data Transfer Failure

F40836 CX32 DRIVE-CLI data sending error

F40837 CX32: Component failure

F40845 CX32: Cyclic Data Transfer Failure

F40851 CX32 (CU): Missing steroid symbol

F40860 CX32 (CU): message failure

F40875 CX32 (CU): Power supply voltage fault

F40885 CX32 (CU): Cyclic data transmission failure

F40886 CX32 (CU): Error sending data

F40887 CX32 (CU): Component failure

F40895 CX32 (CU): Cyclic data transmission failure

F60004 (N, A) armature circuit phase loss

F60005 (N, A) excitation circuit phase loss

F60006 (N, A) power supply monitoring detected undervoltage

F60007 (N, A) power supply monitoring detected overvoltage

F60008 (N, A) incoming power frequency is lower than "Z low incoming power frequency"

F60009 (N, A) incoming power frequency exceeds "Zg incoming power frequency"

F60010 (N, A) current distribution in armature circuit is uneven

F60012 (N, A) P2P-SS: message monitoring time exceeded

F60014 (N, A) parallel interface: message monitoring time exceeded

F60025 (N, A) brush is too short

F60026 (N, A) bearing damaged

F60027 (N, A) motor fan damaged

F60028 (N, A) motor temperature too high

F60029 (N, A) fault: abnormal motor temperature

F60031 (N, A) "Set Actual" difference is too large

F60035 (N, A) motor blocked

F60036 (N, A) armature circuit/excitation circuit interruption

F60038 (N, A) motor overspeed: speed threshold exceeded
Previous:Nothing
Next:Xinjie DS2 series servo maintenance  2023/01/14
Home | CNC maintenance | Servo repair | motor repair | PLC Vision | Touch repair | PLC/HMI | Successful case | information | About jahw
主站蜘蛛池模板: 爱爱视频免费看 | 99久久精品国产一区二区 | 亚洲国产综合专区在线播一一 | 国产欧美综合在线观看第七页 | 97精品国产福利一区二区三区 | 免费人成网站线观看合集 | 成人a视频在线观看 | 国模午夜写真福利视频在线 | 伊人久久综在合线亚洲91 | 日韩久草 | a级毛片毛片免费很很综合 a级毛片在线观看 | 香蕉视频在线网址 | 黄色成年人视频 | 在线观看黄 | 久久久久久尹人网香蕉 | 国产精品中文字幕在线观看 | 午夜在线社区视频 | 亚洲性综合网 | 亚洲一区精品视频在线 | 国产美女一区精品福利视频 | 91好色视频 | 麻豆91国语视频 | 在线观看一区二区精品视频 | 欧美性色xo影院在线观看 | 国产精品αv在线观看 | 国产精品无卡无在线播放 | 日本精品中文字幕在线不卡 | 欧美在线观看免费一区视频 | 日韩 欧美 亚洲国产 | 国产一起色一起爱 | 欧美激情大尺度做爰叫床声 | bbixx在线观看 | 欧美极品福利视频在线播放 | 国产成人久久蜜一区二区 | 国产一级片网站 | 热99re久久精品精品免费 | 久久久这里只有精品加勒比 | 未满十八18周岁禁止免费国产 | 91最新免费观看在线 | 色婷婷综合和线在线 | 国产丝袜护土调教在线视频 |